Precautions for battery operation
1. Prohibition short circuit
Never short circuit battery. It generates very high current which causes heating of the battery and may cause leakage, gassing or explosion that is very dangerous.The poles may be easily short-circuited by putting them on conductive surface.Such outer short circuit may lead to heat generation and damage of the battery.An appropriate circuitry with PCM shall be employed to protect accidental short circuit of the battery pack.
2.  Prohibition Parallel or string battery
3. Mechanical shock
Falling, hitting, bending, etc. may cause degradation of battery characteristics.
4. Prevention of short circuit within a battery pack
Enough insulation layers between wiring and the cells shall be used to maintain extra safety protection.The battery pack shall be structured with no short circuit internally, which may cause generation of smoke or firing.

    hoffumSpecification

    No.

    Item

    General Parameters

    Remark

    1

    Rated Capacity

    20Ah

    standard discharge(0.2C)25±5℃

     

    6% bank for BMS, or self-discharge will damage the battery system.

    2

    Minimum Rated Capacity

    19.6Ah

    3

    Nominal Voltage

    48V

    4

    Cycle Life

     

    Higher than 80% of the Initial Capacity of the Cells

    >800

    ◆Charge: CC@0.5C to54V, then CV till current to 0.05C

    ◆Rest:30min.◆Discharge:1C to10%SOC

    ◆Temperature:25±5℃◆Carry out 800 cycles

    5

    Discharge cut-off voltage

    ≥40V(1C)

    Must remove SOC protection of BMS before testing

    6

    Charging cut-off voltage

    ≤54V

    Control by BMS

    7

    Max Charging voltage

    54.6V

    Higher Voltage cause permanent damage to the battery

    8

    Assembly method

    15S1P

     

    9

    Packing material

    Sheet Metal + Spraying

    panel

    10

    Standard charge

    0.2C current(CC)charge to 54V,then constant voltage (CC)28Vcharge till charge current decline to ≤0.02C

    Charge time :Approx5.5h

    Must be control by BMS with CAN-BUS

    11

    Maximum Charge Current

    20A(15~45℃)

    10~20A (recommended)

    12

    Maximum Continuous Discharge Current

    20A/单次(-10~45℃)

    40A/单次(0~25℃)

     

    10A (recommended)

    10A

    13

    Maximum Pulse

    Discharge Current

    90A/10S

    At 160A continuous current, the BMS will trigger the discharge over current protection

    14

    Operation Temperature Range

    Charge: 0~45℃

    Discharge: -20~65℃

    60±25%R.H.

    15

    Storage Temperature Range

    Less than 1 month:-20~45℃

    60±25%R.H.

    at the shipment state

    Less than 6months:20~35℃

    16

    Weight

    Approx: 11.3kg±5%

     

    17

    Cooling

    Natural cooling

     

    18

    Dimension

    Height: 433±2 mm

     

     

     

     

    Width: 220±1mm

    Length:120±1 mm

    19

    Heating

    None

     

    20

    NTC

    3

    2 for cell

    1for main board

    21

    Comply standard

    EN1175:2020

    ISO13849 PL=c

    IEC62619

    IP54

     

    hoffumStoring the Batteries

    The batteries should be stored at room temperature, charged to about 30% to 50% of capacity.We recommend that batteries be charged about once per half a year to prevent over-discharge.